Minicom Advanced Systems CMG-DCM Network Card User Manual


 
Operator's guide
HTTP server
In addition to configuring the DCM and instruments attached to it, you can also
instruct the on-board Web server to provide data to network clients.
datatransfer.http.server : Select on if you wish to be able to retrieve data from
the DCM over the Web (i.e. HTTP). Once the HTTP server is enabled, you can
browse through the DCM's hard disk using the URL http://mydcm/cgi-
bin/explorefs?path=/.
You may need a username and password to access this service.
HTTP client
The DCM also has the ability to retrieve data from another instrument or server
on your network over HTTP.
datatransfer.http.client : Select on if you wish the DCM to retrieve data from
networked instruments over HTTP.
datatransfer.http.client.url : The URL from which the DCM will collect data by
HTTP.
CD1.0
Continuous Data Format, CD1.0, is a standard method for sending seismic data
over a TCP/IP network. The DCM module can send and receive data in CD1.0
format to a specific CD1.0-compatible device or NDC.
Some installations of the DCM have multiple CD1.0 senders. In this case, there
December 2005 57