Appendix 3 Steps to Create a Program for L Series
APPENDICES
(3) In the "Refresh program generation tool for MELSECNET (II) local station"
window, prepare the conditions for a new program.
Item Description
PLC type Select "Q25H".
I/O No. of A1SJ71AP23Q/A1SJ71AR23Q/
A1SJ71AT23BQ
Enter the I/O number of the slot on which the local
module is mounted. This setting is intended for the
start number of a module to be accessed by the
FROM/TO instruction. Before entering the I/O
number, check the actual system. An I/O number
different from that of the actually mounted module
can cause the CPU module to stop.
Network type (mode)
Select the network type (mode) that is set up in the
network parameters in the master station.
Sequence program
to be created
BW receive program of
master station in third tier
Check the box if a station into which the refresh
program is to be included is a third tier local station.
LRDP instruction receive
program
LWTP instruction receive
program
Check the box if the program of the master station
includes the transient instruction to be given to
"Station on which a local station data link module is
mounted".