NEC NEAX2400 Network Cables User Manual


 
CHAPTER 5 ND-70185 (E)
Page 86
Revision 3.0
DATA PROGRAMMING
Assignment of FCH Related Data
STEP 4: ACAN
Assign the Fusion Connection Index Code (FCIC) and the LENs on an adjacent FPC basis. Figure 5-
34 shows a sample data sheet for Node A.
Note:
It is not necessary to assign the same number as trunk and FCIC. However, FCIC numbers between adja-
cent nodes must be identical.
Figure 5-34 ACAN Sample Data Sheet
The ACAN command display should look similar to the following:
Figure 5-35 ACAN Command Display (example)
FPC = 2 FCIC = 1 C_LENS = 000010
FPC = 2 FCIC = 2 C_LENS = 000011
FPC = 2 FCIC = 3 C_LENS = 000012
FPC = 2 FCIC = 4 C_LENS = 000013
: : :
LCN
LCN
LCN
LCN
LCN
LCN
NCN
1
2
C_RT=10
Node A
Node B
FCIC=1
FCIC=1
FCIC=2
FCIC=n
FCIC=2
FCIC=n
TRK 1
TRK 10
TRK 3
TRK 31
TRK 32
TRK 40
:
:
:
:
Adjacent-Node
Self-Node
A sample data sheet at Node A is as follows.
FCIC number must be identical
FPC
For Help, press F1
ACAN (Assignment of CIC Number between Adjacent Node for Network)
FCIC
21
Fusion Circuit Identification Code
Assign Adjacent FPC
C_LENS
C_LENS
WRT?
000011