NEC NEAX2400 Network Cables User Manual


 
CHAPTER 5 ND-70185 (E)
Page 108
Revision 3.0
DATA PROGRAMMING
Assignment of FCH Related Data
STEP 6: ACAN
Assign the Fusion Connection Index Code (FCIC) for the Next Node.
FPC (Fusion Point Code): Assign FPC number of the Self-node.
FCIC (Fusion Connection Index Code): Assign Fusion CIC of the Self-node.
C_LENS (Connection_LENS): Assign DTI LENS data (Bch data), specified in STEP 2.
Figure 5-56 Sample Data Assignment (ACAN)
STEP 7: AFRT
Set Connection Route Numbers of the Speech Channels for the FCHN which was assigned in STEP 4.
FCHN (FCH Number): Assign FCHN, specified in STEP 4.
C_RT (Connection Route): Assign Connection Route of the Speech Channels, specified in STEP 2.
Figure 5-57 Sample Data Assignment (AFRT)
FCH
FGH
DTI
ROUTER
Nail Down Connection
T1
RT13
RT14
RT1
FPC
FCIC
10
1
C_LENS
002010
ACAN command parameters
Note
Note: This setting is a sample.
FPC=10
FPC
(Self-node)
speech
FCIC1: 002010
FCIC2: 002011
FCIC3: 002012
FCIC10: 002022
to CPU
FCHN
CNT
1
2
1
1
C_RT
AFRT command parameters
Note 1
Note 2
assigned
in STEP 4
PBX
FCH
FGH
DTI
ROUTER
Nail Down Connection
T1
speech
RT13
RT14
RT1
FCHN=1
to CPU
Note 1: This setting is a sample.
Note 2: A maximum of 8 C_RT can be programmed.