NEC NEAX2400 Network Cables User Manual


 
ND-70185 (E) CHAPTER 7
Page 167
Revision 3.0
TROUBLESHOOTING
23-W FCH Alternate Routing Start Notification
10. 23-W FCH Alternate Routing Start Notification
This message is displayed when the indicated FCH card of self-Node becomes inoperative. This message is also
displayed when the card is placed in make busy status by MNT 3 switch operation. In addition, when the FCH
of the adjacent node becomes inoperative, this message is displayed.
Figure 7-24 23-W FCCH Alternate Routing Start Notification
11. 23-X FCH Alternate Routing End Notification
This message is displayed when an inoperative FCH card of self-Node resumes its operation. Therefore, when
the card is placed in make idle status by MNT 3 switch operation, this message is also displayed.
Figure 7-25 23-X FCCH Alternate Routing End Notification
1. xx0x 0000 0000 0000 2. 0000 0000 0000 0000 3. 0000 .........
MG
U
G
FCH Mounting Location
FCH Mounting Location
MG: Module Group
U: Unit (0-3)
G: Group (00-23)
FCH CKT No.
Circuit Number of FCH (0 - 7)
b0b7
b0b7
1. xx0x 0000 0000 0000 2. 0000 0000 0000 0000 3. 0000 .........
MG
U
G
FCH Mounting Location
FCH Mounting Location
MG: Module Group
U: Unit (0-3)
G: Group (00-23)
FCH CKT No.
Circuit Number of FCH (0 - 7)
b0b7
b0b7