NEC NEAX2400 Network Cables User Manual


 
ND-70185 (E) CHAPTER 5
Page 69
Revision 3.0
DATA PROGRAMMING
Assignment of Numbering Data for Telephone Numbers
STEP 3: ASPAN
Assign special access code data for the Telephone Numbers using the ASPAN command.
SRV=TELN is the data for Telephone Numbers.
Figure 5-16 ASPAN Sample Data Sheet
Figure 5-17 ASPAN Command Display
Note:
The Numbering Plan data for the LDM and/or NDM cannot use separate Tenant Numbers (TN). Therefore,
be sure to assign the following data on the ASYDL command.
ASYDL command, SYS1, INDEX 800
b1 = 1 (ASPAL command tenant data table development on LDM = Common)
b2 = 1 (ANPDL command tenant data table development on LDM = Common)
SRV (Kind of Service)
TELN: Telephone Number
- ASPAN Data Sheet (example)
- NCN (Node A)
4 x x x x x
Telephone Number
6 digits
TN = 1 ACC = 4 CI = N (Normal) SRV = TELN NND = 6
TN = 1 ACC = 4 CI = H (Hooking) SRV = TELN NND = 6
ACC (Access Code): max 6 digits
CI (Connection Index)
N: Normal
H: Hooking
B: Busy
NND (Maximum Number of Digits):
1 - 16 (digits)
SRV (Kind of Service)
TELN: Telephone Number
Note
1
TN
SRV
TELN
ASPAN (Assignment of Special Access Code Data for Network Data Memory)
4
1st DC
CI
NND
N
6
Note:
Available SRV is Telephone Number only. For more information, see the “Office Data Specification”.