NEC NEAX2400 Network Cables User Manual


 
CHAPTER 4 ND-70185 (E)
Page 46
Revision 3.0
INSTALLATION
Connecting Cables
4.3.3 When not using the cable unit SR1201 ETIF CAU-n
When your system doesn’t use the cable unit classified as SR1201 ETIF CAU-n, perform the 10 BASE-
T connections as instructed below:
1. Depending on your system configuration, connect the 10 BASE-T straight cable(s) between the
HUB (PA-M96) and LANI (PZ-PC19) cards. Use the cable UTP CTG5 ST CA-O, which must be
provided by the user.
When a single LANI is used for each CPR (Slot 00 only) and the HUB is in a dual configuration,
connect HUB#0 to LANI#0 and HUB#1 to LANI#1, using two 10 BASE-T cables.
When dual LANIs are used in both Slot 00 and 03 of CPR#0/CPR#1, use at least two HUB cards
as separate 10 BASE-T connection terminals: One HUB for the internal LANI (LANI-A in Slot 00
0f each CPR) and the other for the external LANI (LANI-B: in Slot 03 of each CPR) The external
LANI is available for Series 7300 Release 3 software or later.
2. When HUB is in a dual configuration, connect the 10 BASE-T cross cable between the HUB cards.
Use the cable UTP CTG5 CRS CA-F, which must be provided by the user.
When using more than two HUB cards, connect the cross cable(s) for the remaining HUB cards,
except the HUB card used for the MAT connection.
3. Connect the 10 BASE-T straight cable(s) between the HUB and FCH (PA-FCHA) cards. Use the
following cables, which must be provided by the user.
UTP CTG5 ST CA-F: When the HUB and FCH are in the same PIM (PIM0)
UTP CTG5 ST CA-O: When the HUB and FCH are in different PIMs
When FCH is in a dual configuration, connect FCH#0 to the HUB#0 side, and FCH#1 to the HUB#1
side.
4.3.4 Procedure for 4-IMG System
When your system is 4-IMG type, the procedure for 10 BASE-T connection is as follows. Because the
HUB (PA-M96) can be mounted anywhere in a PIM of any IMG, the Ethernet cables must be arranged
by the user, depending on the system configuration.
1. Depending on your system configuration, connect the 10 BASE-T straight cable(s) between the
HUB (PA-M96) and LANI (PZ-PC19) cards. Use the following cable, prepared by the user.
UTP CTG5 ST CA-O: When the HUB and LANI are in the same IMG (IMG0)
UTP CTG5 ST CA-X: When the HUB and LANI are in different IMGs
When a single LANI is used for each CPR (Slot 00 only) and the HUB is in a dual configuration,
connect HUB#0 and HUB#1 to LANI#1 using two 10 BASE-T cables.