NEC NEAX2400 Network Cables User Manual


 
CHAPTER 8 ND-70185 (E)
Page 172
Revision 3.0
EX- FCCS
EX-FCCS Network Configuration
2.3 Conditions for Network Establishment (NEAX2400 IMX to NEAX2400 IMX Connection)
Conditions for establishing a FCCS network (NEAX2400 IMX to NEAX2400 IMX) are shown below.
1. Each Fusion Network can accommodate a maximum of 253 network IDs.
2. Each Fusion Network can accommodate a maximum of 899 logical routes.
3. The NCN and NDM exist individually in each Fusion Network.
Figure 8-3 NEAX2400 IMX to NEAX2400 IMX Connection
Network configuration of the NEAX2400IMX to NEAX2400IMX connection is as follows.
FPC1
(NCN)
FPC2
FPC4FPC3
FPC1
(NCN)
FPC2
FPC3 FPC4
Fusion Network (B)
In this Fusion Network,
NDM (a) is used.
In this Fusion Network,
NDM (b) is used.
FPC1
(NCN)
FPC2
FPC4FPC3
LGRT3
LGRT3
LGRT4
In this Fusion Network,
NDM (c) is used.
: EX-FCCS
: Fusion Group (FUG)
: FCCS
Fusion Network (A)
Fusion Network (C)
LGRT1, 2
LGRT899
LGRT1, 2
LGRT200
LGRT100
LGRT899
Network configuration of the NEAX2400 IMX to NEAX2400 IMX connection is as follows.