NEC NEAX2400 Network Cables User Manual


 
ND-70185 (E) CHAPTER 7
Page 161
Revision 3.0
TROUBLESHOOTING
23-U FCH Status Information
9.1 FLTINF = 00H Initial Setting Failure
This message is displayed when the Ethernet Controller Initial Setting ends in failure. The detailed information
is indicated in the following format.
Figure 7-17 23-U FCCH Status Notification - Initial Setting Failure
ETHER Results
00H: Normal
01H: ETHER Controller Reset Impossible 03H: ETHER Controller Initial NG
02H: Configuration Error 04H: ETHER Controller Initial NG
1. xx 0x 00 xx xx xx xx xx 2. xx xx xx xx 0000 0000.........
MG
U
G
FCH Mounting Location
FCH CKT No.
TRC
RS
00
MG: Module Group
U: Unit (0-3)
G: Group (0-23)
TRC: Trace Confirmation Bit
(0/1 = Status Notification / Primitive Trace)
RS: Receive / Send Primitive Trace (not effective)
FCH CKT No. = Circuit No. of FCH
00
FLTINF: 00H = Initial Setting Failure
HDLC Results
HDLC Results: 00H = Normal
ETHER Results
ETHER Results: See below.
b7 b0
b7 b0
b7 b0
b7 b0
b7 b0
b7 b0
MAC Address of FCH
b7 b0
b7 b0
Other Results: 00H = Normal
Other Results
:
:
:
:
6 Bytes
"Initial Setting Failure"