Utility Commands
614
ProSafe M4100 and M7100 Managed Switches
no rmon alarm
This command deletes the rmon alarm entry.
Format no rmon alarm <alarm number>
Mode
rmon hcalarm
This command sets the rmon hcalarm entry in the High Capacity RMON alarm mib group.
Format
rmon hcalarm <alarm number> <variable> <sample interval>
<sampling type> rising-threshold high <value> low
<value> falling-threshold high <value> low <value>
startup <rising/falling/rising-falling> owner <string>
Mode
Sample Interval The interval in seconds over which the data is sampled and compared with the rising and
falling thresholds.
The range is 0 to 2147483647. The default is 0.
Alarm Sample Type The alarm sample type. The method of sampling the selected variable and calculating the
value to be compared against thresholds. Possible types are Absolute or Delta.
Alarm Rising
Threshold Value
The alarm rising threshold for the sample statistics.
Alarm Falling
Threshold Value
The alarm falling threshold for the sample statistics.
Alarm Startup
Alarm
The alarm that may be sent. Possible values are Rising Alarm, Falling Alarm or both.
Alarm Owner string The alarm owner. The owner string associated with the alarm entry.
Global Config
Global Config
Parameter Description
hcalarm alarm
number
The identifier of the hcalarm instance.
High Capacity
Alarm Variable
The object identifier of the particular variable to be sampled. Only variables that resolve to an
ASN.1 primitive type of integer.
High Capacity
Alarm interval
The interval in seconds over which the data is sampled and compared with the rising and
falling thresholds. The range is 1to 2147483647.
High Capacity
Alarm Sample Type
The method of sampling the selected variable and calculating the value to be compared
against thresholds. Possible types are Absolute or Delta.
Rising-Threshold
High Value
High capacity alarm rising threshold absolute value high. The upper 32 bits of the absolute
value for threshold for the sampled statistics.
Parameter Description