Nortel Networks 1000ASE-XD Switch User Manual


 
Chapter 3 Using the console interface 147
Using the BayStack 420 10/100/1000 Switch
Console/Comm Port Configuration screen
The Console/Comm Port Configuration screen (Figure 68) allows you to
configure and modify the console/comm port parameters and security features of a
standalone switch or any participating switch in a stack configuration.
To open the Console/Comm Port Configuration screen:
Display configuration
complete?
This field allows you to determine whether the configuration information received
from NVRAM/DRAM (depending on what is selected in the Display Messages
From field) is complete. Use the spacebar to toggle between the options.
Default No
Range No, Yes
Clear Messages From This field allows you to clear the information messages from DRAM, NVRAM or
both. If you clear DRAM messages, existing NVRAM messages are copied into
DRAM. After a system reset, all existing NVRAM messages are copied to
DRAM. Use the spacebar to toggle between the options.
Default None
Range None, NVRAM, DRAM + NVRAM
Choose Console/Comm Port Configuration (or press o) from the main menu.
Table 32 System Log screen fields (continued)
Field Description