167
Menu
Sub menu
Parameter 1 Parameter 2 Parameter 3 Parameter 4
Turn F1 to select. Turn F2 to select. Turn F3 to select. Turn F4 to select. Turn F5 to select.
DSK2 DSK2 4 Parameter Type Width Direc
Edge Setting range Off, Border, Drop,
Shadow, Outline
0 to 4 0, 45, 90, 135,
180, 225, 270, 315
Default value Off 2 0
DSK2 5 Parameter Hue Sat Lum Load ↓
EdgeCol Setting range 0.0 to 359.9 0.0 to 100.0 0.0 to 108.0 White, Yellow,
Cyan, Green,
Magenta, Red,
Blue, Black
Default value 0.0 0.0 0.0 Black
DSK2 6 Parameter Mask Invert
Mask Setting range Off, Manual, 4:3 On, Off
Default value Off Off
DSK2 7 Parameter Left Top Bottom Right
MaskAdj Setting range −50.00 to 50.00 −50.00 to 50.00 −50.00 to 50.00 −50.00 to 50.00
Default value –25.00 25.00 –25.00 25.00
TIME TIME 1 Parameter TransTime Unit
BKGD Setting range 0 to 33s
(When 59.94 Hz is
selected)
0 to 999f Frame, Sec
Default value 1s 0f Sec
TIME 2 Parameter TransTime Unit
KEY Setting range 0 to 33s
(When 59.94 Hz is
selected)
0 to 999f Frame, Sec
Default value 1s 0f Sec
TIME 3 Parameter TransTime Unit
PinP1 Setting range 0 to 33s
(When 59.94 Hz is
selected)
0 to 999f Frame, Sec
Default value 1s 0f Sec
TIME 4 Parameter TransTime Unit
PinP2 Setting range 0 to 33s
(When 59.94 Hz is
selected)
0 to 999f Frame, Sec
Default value 1s 0f Sec
TIME 5 Parameter TransTime Unit
DSK1 Setting range 0 to 33s
(When 59.94 Hz is
selected)
0 to 999f Frame, Sec
Default value 1s 0f Sec
TIME 6 Parameter TransTime Unit
DSK2 Setting range 0 to 33s
(When 59.94 Hz is
selected)
0 to 999f Frame, Sec
Default value 1s 0f Sec
TIME 7 Parameter TransTime Unit ENBL
AUX1 Setting range 0 to 33s
(When 59.94 Hz is
selected)
0 to 999f Frame, Sec Enable, Disable
Default value 1s 0f Sec Enable
8. Setting menu table