Pin Assignments
D-8
3160-A2-GB21-80March 1999
EIA-530-A Port Interface Connector
The EIA-530-A Port interface connector information is shown in Table D-7.
Table D-7. EIA-530-A Port Interface Connector
Signal
Circuit
Mnemonic
ITU-T
Number
Direction Pin
Shield 1
Signal Common AB 102A 7
Signal Common AC 102B 23
Transmitted Data BA 103 To DSU/CSU 2 (A)
14 (B)
Received Data BB 104 From DSU/CSU 3 (A)
16 (B)
Request-to-Send CA 105 To DSU/CSU 4 (A)
19 (B)
Clear-to-Send CB 106 From DSU/CSU 5 (A)
13 (B)
Received Line
Signal Detector
CF 109 From DSU/CSU 8 (A)
10 (B)
DCE Ready CC 107 From DSU/CSU 6
DTE Ready CD 108/1, /2 To DSU/CSU 20
Transmit Signal
Element Timing
(DTE Source)
DA 113 To DSU/CSU 11 (B)
24 (A)
Transmit Signal
Element Timing
(DCE Source)
DB 114 From DSU/CSU 12 (B)
15 (A)
Receiver Signal
Element Timing
(DCE Source)
DD 115 From DSU/CSU 17 (A)
9 (B)
Local Loopback LL 141 To DSU/CSU 18
Remote
Loopback
RL 140 To DSU/CSU 21
Test Mode TM 142 From DSU/CSU 25