Paradyne 3160 Network Card User Manual


 
SNMP MIB Objects
E-27
3160-A2-GB21-80
March 1999
Where these object identifiers are defined as follows:
H wellKnownCodes – OBJECT IDENTIFIER ::= [ifExtensions 5]
H none – OBJECT IDENTIFIER ::= [wellKnownCodes 1]
H inSyncNoBitErrors – OBJECT IDENTIFIER ::= [wellKnownCodes 2]
H inSyncWithBitErrors – OBJECT IDENTIFIER ::= [wellKnownCodes 3]
H notInSync – OBJECT IDENTIFIER ::= [wellKnownCodes 4]
Enterprise MIB
The variable devConfigAreaCopy under the devConfigAreaCopy group in the
common area of the Enterprise MIB will be fully supported. This variable allows
the entire contents of one configuration area to be copied into another
configuration area.