Operation
3-24
3160-A2-GB21-80
March 1999
5. Select Mgmt.
F1
Edit:
User Alarm Mgmt
F2
F3
6. From the Mgmt Config screen, select Gen.
F1
Mgmt Config:
Gen Trap
F2
F3
7. Press F1 (Next) until the Com Link configuration option appears.
8. Press F2 (PPP) or F3 (SLIP).
F1
Com Link:
Next PPP SLIP
F2
F3
Specifying the Community Name(s) and Access Type(s)
You have the capability of specifying up to two community names (community
name 1 and community name 2) to be used by external SNMP managers when
trying to access objects in the DSU/CSU’s MIB. Once you specify the community
name(s), you must then specify the type of access to the MIB that SNMP
managers in the community are permitted to have.
" Procedure
To specify the community name 1 and its access type:
1. From the top-level menu screen, select Cnfig.
2. Select the configuration option set to be copied into the Edit area by using the
appropriate Function key. Use the scroll keys, if necessary.
3. Select Edit.
4. From the Edit screen, press the
key until the Mgmt selection appears on
the screen.