Paradyne HOTWIREt 7984 Network Card User Manual


 
Configuration Option Tables
A-22
7984-A2-GB20-10February 1999
Table A-9. SNMP Traps Options (3 of 3)
Link Traps
Possible Settings: Disable, Up, Down, Both
Default Setting: Both
Determines if SNMP traps are generated for link up and link down for one of the
communication interfaces.
Disable – No
linkUp
or
linkDown
SNMP traps are generated.
Up – A
linkUp
trap is generated when the 7984 Termination Unit recognizes that one of
the communication interfaces is operational.
Down – A
linkDown
trap is generated when the 7984 Termination Unit recognizes a
failure in one of the communication interfaces.
Both – Sends trap messages for detection of both
linkUp
and
linkDown
.
NOTE: Refer to
linkUp and linkDown
in Appendix B,
Standards Compliance for
SNMP Traps
.
Link Trap Interfaces
Possible Settings: Network, DSX, All
Default Setting: All
Determines if the SNMP
linkUp
, SNMP
linkDown
, and interface-related
enterpriseSpecific
traps are generated for the network interface, DSX port, or both.
Network – SNMP trap messages are generated for the network interface.
DSX – SNMP trap messages are generated for the DSX port.
All – SNMP trap messages are generated for the network T1 interface, COM port and
the DSX ports.