Standards Compliance for SNMP Traps
B-3
7984-A2-GB20-10
February 1999
Enterprise-Specific Traps
EnterpriseSpecific traps indicates that an enterprise-specific event has occurred.
The Specific-trap field identifies the particular trap that occurred. The following
table lists the enterprise-specific traps supported by the unit:
SNMP Trap
Description Possible Cause
enterprisePrimary
ClockFail(1)
A failure of the currently
configured primary clock
source for the unit has
been detected.
The configured clock source
is no longer operational. If
the configured clock source
is the internal clock, the
possible cause may be due
to a failure of one or more of
the unit’s hardware
components.
enterprisePrimary
ClockFailClear(101)
Clock failure has cleared. N/A
enterpriseSelfTestFail(2) A hardware failure of the
unit is detected during the
unit’s self-test. The trap is
generated after the unit
completes initialization.
Failure of one or more of the
unit’s hardware components.
enterpriseDeviceFail(3) An internal device failure. Operating software has
detected an internal device
failure.
enterpriseTestStart(5) A test is running. At least one test has been
started on an interface.
enterpriseConfig
Change(6)
The configuration changed
via the user interface. The
trap is sent after
60 seconds have elapsed
without another change.
This suppresses the
sending of numerous traps
when multiple changes are
made in a short period of
time, as is typically the
case when changing
configuration options.
Configuration has been
changed via the ATI.
enterpriseTestStop(105) All tests have been halted. All tests have been halted on
an interface.
There are no variable-bindings for enterpriseDeviceFail, enterprisePrimary
ClockFail, enterpriseSecondaryClockFail, enterprisePrimaryClockFailClear,
enterpriseSecondaryClockFailClear, and enterpriseConfigChange. The
variable-binding for enterpriseSelfTestFail is devSelfTestResults.