Paradyne HOTWIREt 7984 Network Card User Manual


 
Configuration Option Tables
A-7
7984-A2-GB20-10
February 1999
Table A-3. System Options (2 of 2)
Telco Initiated Loopback
Possible Settings: Enable, Disable
Default Setting: Enable
Determines if the unit will respond to inband loopback commands on the DSX-1
interface. See
Telco-Initiated Tests
on page 5-9.
Enable – The unit will respond to inband loopback commands.
Disable – The unit will not respond to inband loopback commands.
Remote Telco Loopback
Possible Settings: Enable, Disable
Default Setting: Disable
Determines if the unit will perform a Telco-initiated loopback on just the local unit or if
the loopback will be performed on the remote DSL unit. See
Telco-Initiated Tests
on
page 5-9.
Enable – The loopback will be in the remote unit.
Disable – The loopback will be local.