Q-Logic 59021-05 Switch User Manual


 
B Command Line Interface
Set Config Command
B-28 59021-05 A
threshold
Initiates a configuration session by which to generate and log alarms for selected
events. The system displays each event, its thresholds, and sampling interval one
line at a time and prompts you for a value. For each parameter, enter a new value
or press the Enter key to accept the current value shown in brackets. These
parameters must be saved in a configuration and activated before they will take
effect. Refer to the Config Command on page B-7 for information about saving
and activating a configuration. Table B-9 describes the Set Config Threshold
parameters. The switch will down a port if an alarm condition is not cleared within
three consecutive sampling intervals (by default 30 seconds). An alarm is cleared
when the threshold monitoring detects that the error rate has fallen below the
falling threshold.
PrincipalPriority The priority used in the FC-SW-2
principal switch selection algorithm. 1 is
high, 255 is low.
ConfigDescription The name for the configuration. The
default is undefined.
Table B-9. Set Config Threshold Parameters
Parameter Description
Threshold Monitoring Enabled Master enable/disable parameter for all
events. Enables (True) or disables (False)
the generation of all enabled event alarms.
The default is False.
CRCErrorsMonitoringEnabled
DecodeErrorsMonitoringEnabled
ISLMonitoringEnabled
LoginMonitoringEnabled
LogoutMonitoringEnabled
LOSMonitoringEnabled
The event type enable/disable parameter.
Enables (True) or disables (False) the
generation of alarms for each of the
following events:
CRC errors
Decode errors
ISL connection count
Login errors
Logout errors
Loss-of-signal errors
Table B-8. Set Config Switch Parameters (Continued)
Parameter Description