Quantum L100 Computer Drive User Manual


 
Appendix B Fault Symptom Code (FSC) Dictionary
120 Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide
2102 FSC_I2C_NO_
ACKNOWLEDGEMENT
No acknowledge
received from slave
I
2
C 100%
2103 FSC_I2C_UNABLE_TO_
SEND_MESSAGE
Exceeded retry limit
while trying to send
message
I
2
C 100%
2104 FSC_I2C_NO_
RESPONSE_FROM_
HARDWARE
Expected response
from hardware was not
received
I
2
C 100%
2105 FSC_I2C_UNKNOWN_
MESSAGE_
DESTINATION
Message received from
I
2
C bus but destination
is unknown
I
2
C 100%
2106 FSC_I2C_MESSAGE_
TOO_BIG
Message to send over
I
2
C bus is too big (see
path)
I
2
C 100%
2107 FSC_I2C_RCV_
MESSAGE_TOO_BIG
Message received over
I
2
C bus is too big
I
2
C 100%
2108 FSC_I2C_MAILBOX_
FULL
I
2
C mailbox is full I
2
C 100%
2109 FSC_I2C_INVALID_RCV_
ADDRESS
Receiver address in I
2
C
message incorrect
I
2
C 100%
210A FSC_I2C_STUCK_
INTERRUPT
Pending interrupt
status not reset
I
2
C 100%
2200 FSC_UI_NO_RESOURCE UI task initialization
failed
Microcode 100%
2201 FSC_UI_QUEUE_FULL UI queue full Microcode 100%
2202 FSC_UI_ACTION_
IMPOSSIBLE
The UI is not in the
correct state to perform
the requested action
Microcode 100%
FSC Name Description FRU Name Confidence %