64 PARAGON II USER GUIDE
Verify and Save Changes:
1. Press F2 to return to the Selection Menu.
2. The Selection Menu will display with the new computer name highlighted in white.
3. Press Enter to switch to this selected computer.
4. Normal computer access and operation indicates a successful connection.
Note: Repeat the steps on the previous pages for each server to be added to the chain. Name and
test each computer as it is added. Follow the steps below to add the rest of the CIM chain of
servers.
Æ
Insert a new CIM in the chain
Æ
Perform Channel Configuration
Æ
Name the Computer Channel on the CIM tiered Selection Menu
Æ
Verify and Save Changes
Attach new CIM to the existing CIM chain:
1. Remove CIM Terminator from the last CIM’s UTP IN port and set aside.
2. Connect a Category 5e UTP cable to UTP IN port on the CIM that is currently last in the
chain.
3. Connect the other end of this Category 5e UTP cable to the UTP OUT port on the next
CIM/computer currently being added to the chain.
4. Place the CIM Terminator in the added CIM UTP IN port.
5. Power ON computer.
6. Optional: Connect a local user console to the UKVMSC Z-CIM.
Name Computer:
1. At the Selection Menu, press F5 to go to the Administration Menu.
2. Select the Channel Configuration submenu.
3. Select the device channel.
4. Press G to bring up a Channel Configuration menu for the CIM chain.
5. Use the Ç and È keys to highlight the Name field of the computer just connected via CIM.
The channel for this computer is displayed in white. The channel will display in black and the
highlight will turn yellow when it is selected.
6. Press Enter - the highlight will turn blue.
7. Type the desired computer name - the highlight will turn green as you begin to type.
8. Press Enter - the highlight will turn yellow.
9. Press S to save the new name.
Verify and Save Changes:
1. Press F2 to return to the Selection Menu.
2. The Selection Menu will display with the new computer name highlighted in white.
3. Press Enter to switch to this selected computer.
4. Normal computer access and operation indicates a successful connection.
Important: Please following these guidelines to ensure that there is enough power to
support all CIMs in a chain.
- For Paragon I UMT242, 442, 832 and 1664, hardware III and Paragon II firmware and
Paragon II UMTs; in chains up to 20 individual ZCIM units at least one P2ZCIM must be
powered ON; In P2ZCIMs chains from 21 to 42 ZCIM units, at least 15 P2ZCIMs must be
powered ON
- At least 75% of UKVMSPD ZCIMs in the chain must be powered ON in order for the
chain to be recognized by the Paragon unit.