Renesas HS2378KCM01H Network Card User Manual


 
140
6.4.5 Notes on HDI
1.
Note on Moving Source File Position after Creating Load Module
When the source file is moved after creating the load module, the [Open] dialog box may be
displayed to specify the source file during the debugging of the created load module. Select
the corresponding source file and click the [Open] button.
2. Source-Level Execution
Source file
Do not display source files that do not correspond to the load module in the program
window. For a file having the same name as the source file that corresponds to the load
module, only its addresses are displayed in the program window. The file cannot be
operated in the program window.
Step
Even standard C libraries are executed. To return to a higher-level function, enter Step
Out. In a for statement or a while statement, executing a single step does not move
execution to the next line. To move to the next line, execute two steps.
3. Operation During Accessing Files
Do not perform other operations during saving in the [Load Program], [Verify Memory],
[Save Memory], or [Trace] window because this will not allow correct saving to be performed.
4.
Source Window at Program Change
When a program being displayed in the source window is changed and the source file and load
module are reloaded, close and reopen the source window once. If the window is not closed
and reopened, the display will be illegal.
5. Watch
Local variables at optimization
Depending on the generated object code, local variables in a C source file that is compiled
with the optimization option enabled will not be displayed correctly. Check the generated
object code by displaying the [Disassembly] window.
If the allocation area of the specified local variable does not exist, displays as follows.
Example: The variable name is asc.
asc = ? - target error 2010 (xxxx)
Variable name specification
When a name other than a variable name, such as a symbol name or function name, is