Renesas M306H7T3-RPD-E Network Card User Manual


 
M306H7T3-RPD-E User’s Manual 2. Setup
REJ10J0964-0100 Rev.1.00 August 01, 2005 Page 29 of 88
2.7 Self-check
2.7.1 Self-check Procedure
To run the self-check of the emulator, do so as explained here below. While the self-check is in progress, the LEDs will change
as shown in Figure 2.7.
(1) If the user system is connected, disconnect it.
(2) Set the switches in the emulation pod to the factory settings as shown in Figure 2.8.
(3) Within 2 seconds of activating power to the emulator, press the system reset switch on the emulator front panel to switch
the emulator to maintenance mode.
(4) Check the SAFE LED starts blinking and then press the system reset switch again.
(5) The self-check will start. If the normal result is displayed in about 30 seconds, the self-check has terminated normally.
Figure 2.7 LED display in the self-check procedure
Immediately after turning on the power
POWER
SAFE
ERROR
STATUS OF
SYSTEM
RESET
POWER
CLOCK
RESET
RUN
HALT
POWER
SAFE
ERROR
STATUS OF
SYSTEM
RESET
POWER
CLOCK
RESET
RUN
HALT
POWER
SAFE
ERROR
STATUS OF
SYSTEM
RESET
POWER
CLOCK
RESET
RUN
HALT
POWER
SAFE
ERROR
STATUS OF
SYSTEM
RESET
POWER
CLOCK
RESET
RUN
HAL T
POWER
SAFE
ERROR
STATUS OF
SYSTEM
RESET
POWER
CLOCK
RESET
RUN
HA LT
(1) All the LEDs light
Completed normally
: Blinking
: On
: Off
Self-check
Target status error
System status error
(2) SAFE LED blinks
ERROR LED lights
SAFE and ERROR LED blink