Rose electronic 16X Switch User Manual


 
ULTRAMATRIX “UMX” SERIES INSTALLATION AND OPERATIONS MANUAL
34
Share (Default: 2 seconds)
This feature allows other users to take keyboard and mouse control of a computer after a specific time of no
keyboard or mouse activity by a user. To change the Share time for a given profile, select the profile, then the Share
to change and press [Enter]. An input box will display. Type in a new share value in seconds and press [Enter].
Valid share values are 0 to 9999 seconds. The share value is only valid if the profile mode is share.
Scan (Default: 5 seconds)
When a user invokes the scan function, this feature sets the time the video is displayed before switching to the next
sequential computers video. To change the scan rate, select the profile, then the scan rate to change and press
[Enter]. An input box will display. Type in a new scan time and press [Enter]. Valid scan times are 0 to 9999. If the
video is not present during the scan mode, the scan value may be set to low and the monitor cannot synchronize to
the video fast enough to display it. This usually happens with a scan value of 4 or lower. If this problem occurs,
increase the scan value. 0 (zero) is a valid entry but not recommended.
Logout (Default: 240 minutes)
This setting disconnects and logs out a user after the set period of no keyboard or mouse activity. To change the
logout value, select the profile, then the logout time to change and press [Enter]. An input box will display. Type in a
new logout time and press [Enter]. Valid times are 0 to 9999 minutes. A value of 0 (zero) disables the automatic
logout function. If login is enabled for a KVM station, but the Logout time is set to zero, the user remains logged in
until they manually log out using the [Ctrl] L command. (See Table 3, keyboard commands)