Metering
Metering allows you to monitor an audio source connected to the keypanel. The energy of that incoming audio is split into
five (5) bands and displayed on the left side of the keypanel, when enabled.
The dB display range is from 28dB below nominal to 8dB above nominal.
The ranges are as follows:
By default, None is configured for metering.
NOTE: Only one channel can be metered at a time.
FIGURE 37. Metering Explanation
Band 1 100Hz to 400Hz
Band 2 400Hz to 800Hz
Band 3 800Hz to 1.6KHz
Band 4 1.6KHz to 3.2KHz
Band 5 3.2KHz to 15KHz