Sony DVS-A3232 Switch User Manual


 
5-7
ROUTING SWITCHER SYSTEM (E)
5-1. Setting Items of the Primary Station
ENABLE ACTIVE UNIT FOR STATION NUMBER DVS-V6464B V2.10 STATION NUMBER 1
1 2 3 4 5 6 7 8 9 10 1112131415 1617181920
+
001-020 M E E E E E E E E E E E E E E E E E E E
021-040 E E E E E E E E E E E E E E E E E E E E
041-060 E E E E E E E E E E E E E E E E E E E E
061-080 E E E E E
081-100
101-120
121-140
141-160
161-180
181-200
201-220
221-240
241-254 * * * * * *
Ctrl-E:RETURN TO MENU
F : SET ACTIVE UNIT NUMBER
Purpose
This menu is used to enable the units connected to the S-
BUS data link to communicate.
Setting Procedure
1. Select menu item [F].
2. Press the cursor keys to select the secondary station
whose communication will be valid.
3. When [Enter] is pressed, the setting displayed will
change (“E” blank “E”). Only the secondary
stations displayed with “E” are valid. (“M” indicates
the primary station.)
4. When [Ctrl] _ [E] is pressed, the menu screen will be
displayed.
n
As the response will become slower if there are many
secondary stations, make the secondary stations not
connected invalid.
*” indicates out of the control area.
Example of Setting Screen
m
1. Station ID of the primary station is always regardless
of the DIP switch setting on the CPU board.
2. Station ID of the secondary station is deter mined with
the DIP switch setting. Do not assign the same
number on two or more units as station ID on both
standard S-BUS and monitor S-BUS.
Number that can be registered as secondary station ID
are 2 to 254.
G: UPDATE BACKUP CONTROLLER
Purpose
This menu is used to copy the table data stored in the main
CPU board of the primary station to the backup CPU
board.
This setting is valid only when the backup CPU board is
installed in the primary station.
Setting Procedure
1. Select menu item [G]. The message “This process
requires about n minutes. Execute? (y/n)” will be
displayed at the bottom of the screen.
Ver. 2.00 : n=5
Ver. 1.00 : n=7
2. Table data copying is performed when [Y] is pressed.
To cancel copying, press [N].
3. After copying, “PROGRAM TABLE? (y/n)” may be
displayed at the bottom of the screen. In this case,
press [Y].
m
1. The ROM version of the main CPU board and that of
the backup CPU board must be the same. If different
versions are used, the unit may hang up due to copy-
ing. Remove the backup CPU board when this occurs.
The above occurs because a new table data can not be
run on the old version software.
2. It takes about seven minutes to copy the table data.
The copy makes other operations slow.
3. The table data of transcode from RS-422A to S-BUS
(set at the menu item [U] of a secondary station) is not
copied to the backup CPU board.
4. When you copy the data of main CPU to backup CPU
on the menu screen [G : UPDATE BACKUP CON-
TROLLER] of the primary station or a secondary
station, you can abort the operation by pressing [Ctrl]
_ [D].
However you should copy again for the data of the
backup CPU is not correct if aborted. Even if you do
not copy again, the data will be renewed in one hour
approximately by the auto backup function.