TABLE 7-5 lists the Virtualization Engine Events.
TABLE 7-5 Storage Automated Diagnostic Environment Event Grid for Virtualization Engine
Category Component EventType Sev Action Description
virtualization
engine
enclosure Alarm Yellow Volume E00012 on
v1a changed
mapping.
virtualization
engine
enclosure Alarm.log Yellow Change in Port
Statistics on
virtualization
engine v1a
virtualization
engine
enclosure Audit [
Info ] Auditing a
Virtualization
Engine called v1a
Information:
Audits occur every
week and send a
detaileddescription of
the enclosure to the
Sun Network Storage
Command Center
(NSCC)
virtualization
engine
oob Comm_
Established
Communication
regained with
virtualization
engine v1a
virtualization
engine
oob Comm_
Lost
Down Y [
Info/Action ]
Lost
communication
withvirtualization
engine v1a
Information:
Ethernet connectivity
to the virtualization
engine unit has been
lost.
Recommended action:
1. Check Ethernet
connectivity to the
virtualization
engine.
2. Make sure the
virtualization
engine is boosted
correctly.
3. Verify that the
TCP/IP settingson
the virtualization
engine are correct.
4. Replace the
virtualization
engine if necessary.