126 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide March 2002
70005 Write error is detected by master.
If the initiator is master, then it has detected
a write error on a member within a mirror
drive.
If a spare drive is available, it will be
brought in and used to replace the failed
drive. If no spare is available, replace the
failed drive with a new drive.
70006 virtualization engine-to-virtualization
engine communication has failed.
Internal error. Update firmware.
70007 Rebuild is aborted with write error. This
means the primary drive cannot write to
the drive being built.
If a spare drive is available, it will be
brought in and used to replace the failed
drive. If no spare is available, replace the
failed drive with a new drive.
70008 Read error is reported by follower. If the
initiator is master, then its follower has
detected a read error on a member within a
mirror drive.
If a spare drive is available, it will be
brought in and used to replace the failed
drive. If no spare is available, replace the
failed drive with a new drive.
70009 Read error is detected by master. If the
initiator is master, then it has detected a
read error on a member within a mirror
drive.
If a spare drive is available, it will be
brought in and used to replace the failed
drive. If no spare is available, replace the
failed drive with a new drive.
70010 CleanUp configuration table is completed.
70020 SAN physical configuration has changed. If unintentional, check condition of drives.
70021 Drive is offline. If unintentional, check condition of drives.
70022 virtualization engine is offline. If unintentional, check condition of drives.
70023 Drive is unresponsive. Check condition of drives.
70024 For Sun StorEdge T3+ array pack: Master
virtualization engine has detected the
partner virtualization engine’s IP Address.
70025 For Sun StorEdge T3+ array pack: Master
virtualization engine is unable to detect the
partner virtualization engine’s IP Address.
Check the Ethernet connection between the
two virtualization engines.
70030 SAN configuration changed by SV SAN
Builder.
70040 Host zoning configuration has changed.
70050 MultiPath drive Failover. Check MultiPath drive.
70051 MultiPath drive Failback.
70098 Instant Copy degrade. If no spare is available, replace the failed
drive with a new drive.
70099 Degrade because the drive has disappeared. Reinsert the missing drive, or replace it
with a drive of equal or greater capacity.
TABLE A-1 SRN and SNMP Reference
SRN Description Corrective Action