Sun Microsystems 3900 Series Computer Drive User Manual


 
56 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide March 2002
host lun.VE Alarm- Red Y [ Info ] The state of
lun.VE.c14t50020
F2300003EE5d0s2.
statusA on
diag.xxxxx.xxx.com
changed from OK to
ERROR
(target=ve:diag244-
ve0/90.0.0.40)
luxadm display
reported achange in
the port status of
one of its paths. The
Storage Automated
Diagnostic
Environment then
tries to find to
which enclosure this
path corresponds by
reviewing its
database of Sun
StorEdge T3+ arrays
and virtualization
engines.
host ifptest Diagnostic
Test-
Red Y ifptest (diag240) on
host failed.
host qlctest Diagnostic
Test-
Red qlctest (diag240) on
host failed.
host socaltest Diagnostic
Test-
Red socaltest (diag240) on
host failed.
host enclosure PatchInfo [
Info ] New patch
and package
information
generated.
Send changes to the
output of showrev -
p and pkginfo -|.
host enclosure backup [
Info ] Agent Backup Backup of the
configuration file of
the agent.
TABLE 5-1 Storage Automated Diagnostic Environment Event Grid for the Host (Continued)