Chapter 8 Troubleshooting the Sun StorEdge T3+ Array Devices 103
For Internal Use Only
T1/T2 Notification Events
The example below shows a typical port failure event
FIGURE 8-1 Storage Service Processor Event
Site : Lab 3286 - DSQA1 Broomfield
Source : diag.xxxxx.xxx.com
Severity : Error (Actionable)
Category : Switch
DeviceId : switch:100000c0dd00b682
EventType: StateChangeEvent.M.port.8
EventTime: 01/30/2002 11:17:22
’port.8’ in SWITCH diag209-sw2a (ip=192.168.0.32) is now Not-Available
(status-state changed from ’Online’ to ’Offline’):
INFORMATION:
A port on the switch has logged out of the fabric and gone offline
PROBABLE-CAUSE:
1. Verify cables, GBICs and connections along Fibre Channel path
2. Check Storage Automated Diagnostic Environment SAN Topology GUI to
identify failing segment of the data path
3. Verify correct FC switch configuration
----------------------------------------------------------------------
Site : Lab 3286 - DSQA1 Broomfield
Source : diag.xxxxx.xxx.com
Severity : Warning
Category : Switch
DeviceId : switch:100000c0dd00b682
EventType: LogEvent.MessageLog
EventTime: 01/30/2002 11:17:22
Change in Port Statistics on switch diag209-sw2a (ip=192.168.0.32):
Port-8: Received 9746 ’InvalidTxWds’ in 0 mins (value=9805 )