Sun Microsystems 3900 Series Computer Drive User Manual


 
Chapter 2 General Troubleshooting Procedures 9
For Internal Use Only
2. Using Storage Automated Diagnostic Environment Topology GUI, determine
which virtualization engine is in the path you need to disable.
3. Use the world wide name (WWN) of the virtualization engine that is in the
unconfigure command, as follows:
4. Verify that I/O has halted.
This halts the I/O only up to the A3/B3 link (see
FIGURE 2-2). I/O continues to move
over the T1 and T2 paths, as well as the A4/B4 links to the Sun StorEdge T3+ array.
# cfgadm -c unconfigure c2::2b000060220041f4
# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 scsi-bus connected configured unknown
c0::dsk/c0t0d0 disk connected configured unknown
c0::dsk/c0t1d0 disk connected configured unknown
c1 scsi-bus connected configured unknown
c1::dsk/c1t6d0 CD-ROM connected configured unknown
c2 fc-fabric connected unconfigured unknown
c2::210100e08b23fa25 unknown connected unconfigured unknown
c2::2b000060220041f4 disk connected unconfigured unknown
c3 fc-fabric connected configured unknown
c3::210100e08b230926 unknown connected unconfigured unknown
c3::2b000060220041f9 disk connected configured unknown
c4 fc-private connected unconfigured unknown
c5 fc connected unconfigured unknown