110 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002
The following table lists all of the events for the Sun StorEdge T3+ array.
Category Component EventType Sev Action Description Information
t3 power.temp Alarm+ The state of
power.u1pcu1.PowTe
mp on diag213
(ip=xxx.20.67.213) is
Normal
t3 disk.port Alarm- Red Y [
Info/Action ] The
state of
disk.u1d1.
Port1State
on Sun
StorEdge T3+ array
t300 changedfromOK
to failed.
Information: The Sun
StorEdge T3+ array
has reported that one
port of a dual-ported
disk has failed.
Recommended action:
1. Telnet to affected
Sun StorEdge T3+
array
2. Verify disk state in
fru stat, fru list,
and vol stat.’
t3 interface.
loopcard.cab
le
Alarm- Red Y [
Info/Action ] The
state of
loopcable.u1l1.CableSt
ate changed from OK
to failed.
Drive Status
Messages:
Value Description
0 Drive mounted
2 Drive present
3 Drive is spun up
4 Drive is disable
5 Drive has been
replaced
7 Invalid system area
on drive
9 Drive not present
D Drive disabled;
drive is being
reconstructed
S Drive substituted
Information: The Sun
StorEdge T3+ array
has reported that a
loopcard is in a failed
state.
Recommended action:
1. Telnet to affected
Sun StorEdge T3+
array.
2. Verify tje loopcard
state with fru stat.
3. Verify the
matching firmware
with the other
loopcard.
4. Re-enable the
loopcard if
possible (
enable
u (encid)|[1|2]
). Replace loopcard
if necessary.
5. Re-enable the disk
if possible
6. Replace the disk, if
necessary.