Sun Microsystems 3900 Series Computer Drive User Manual


 
110 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide March 2002
The following table lists all of the events for the Sun StorEdge T3+ array.
Category Component EventType Sev Action Description Information
t3 power.temp Alarm+ The state of
power.u1pcu1.PowTe
mp on diag213
(ip=xxx.20.67.213) is
Normal
t3 disk.port Alarm- Red Y [
Info/Action ] The
state of
disk.u1d1.
Port1State
on Sun
StorEdge T3+ array
t300 changedfromOK
to failed.
Information: The Sun
StorEdge T3+ array
has reported that one
port of a dual-ported
disk has failed.
Recommended action:
1. Telnet to affected
Sun StorEdge T3+
array
2. Verify disk state in
fru stat, fru list,
and vol stat.’
t3 interface.
loopcard.cab
le
Alarm- Red Y [
Info/Action ] The
state of
loopcable.u1l1.CableSt
ate changed from OK
to failed.
Drive Status
Messages:
Value Description
0 Drive mounted
2 Drive present
3 Drive is spun up
4 Drive is disable
5 Drive has been
replaced
7 Invalid system area
on drive
9 Drive not present
D Drive disabled;
drive is being
reconstructed
S Drive substituted
Information: The Sun
StorEdge T3+ array
has reported that a
loopcard is in a failed
state.
Recommended action:
1. Telnet to affected
Sun StorEdge T3+
array.
2. Verify tje loopcard
state with fru stat.
3. Verify the
matching firmware
with the other
loopcard.
4. Re-enable the
loopcard if
possible (
enable
u (encid)|[1|2]
). Replace loopcard
if necessary.
5. Re-enable the disk
if possible
6. Replace the disk, if
necessary.