140 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide March 2002
TABLE B-4 Other SUNWsecfg Error Messages
Message Description and Cause of Error Suggested Action
Common to all
components
If the Sun StorEdge 3900 or 6900 series
has multiple (more than two) failures
(for example, both virtualization
engines and two switches are down),
the getcabinet tool might not
determine the correct cabinet type. In
this example, the getcabinet script
might determine the device to be a Sun
StorEdge 3900 series when, in reality, it
is a Sun StorEdge 6900 series.
Set the BOXTYPE variable as follows:
BOXTYPE=6910; export BOXTYPE
checkdefaultconfig
Could not determine the Sun StorEdge
system type.
Multiple components might be down
and the getcabinet command could not
determine the Sun StorEdge series type
(3910, 3960, 6910, or 6960).
Try using the command line interface
(CLI) by setting the BOXTYPE
environment variable to one of the four
values.
For example, BOXTYPE=3910; export
BOXTYPE).
setdefaultconfig The system could not determine the
Sun StorEdge system type.
Try using the command line interface
(CLI) by setting the BOXTYPE
environment variable to one of the four
values.
For example, BOXTYPE=3910; export
BOXTYPE).