130 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002
54 Unauthorized cabling configuration. • Check cabling.
57 Too many HBAs attempting to log in. • Check cabling.
60 Node mapping table cleared using SW2. • No action required.
62 Improper SW2 setting. • Correct SW2 setting.
• Cycle virtualization engine power.
126 Too many virtualization engines in SAN. • Remove the extra virtualization engine.
• Cycle virtualization engine power.
130 Heartbeat connection between
virtualization engines is down.
• Correct problem.
• Cycle the power on the follower
virtualization engine.
400 - 599 Device side interface driver errors:
409 FC device-side type code invalid. • Cycle power
• If problem persists, replace virtualization
engine.
434 Too many elastic store errors to continue.
Elastic store errors result from a clock
mismatch between transmitter and receiver
and indicates an unreliable link. This error
can also occur if a device in the SAN loses
power unexpectedly.
• Check for faulty component and replace.
• Cycle the power on the follower
virtualization engine.
TABLE A-4 Service Codes