Sun Microsystems 3900 Series Computer Drive User Manual


 
Appendix B SUNWsecfg Error Messages 135
TABLE B-2 Sun StorEdge Network FC Switch-8 and Switch-16 Switch SUNWsecfg Error Messages
Message Description and Cause of Error Suggested Action
Common Switch Sun StorEdge system type entered,
${cab_type}, does not match system
type discovered, ${boxtype}.
Either call the command with the
-f force option to force the series
type, or do not specify the cabinet type
(no -c option).
Common Switch 1. Unable to obtain lock on switch
${switch}. Another command is
running.
1. Another switch command might be
updating the configuration. Check
listavailable -s.
2. If the switch in question does not
appear, check for the existence of
the lock file directly by typing ls
-la /opt/SUNWsecfg/etc (look
for .$switch.lock).
3. If the lock is set in error, use the
removelocks -s command to
clear it.
checkswitch 1. Current configuration on $switch
does not match the defined
configuration.
2. One of the predefined static switch
configuration parameters, that can
be overridden for special
configurations such as NT connect
or cascaded switches, is set
incorrectly.
1. Select View Logs or directly view
$LOGFILE for more details.
2. Re-run setupswitch on the
specified $switch.
listavailable No Sun StorEdge network FC switch-8
or switch-16 switch devices are
available. They are either not found, or
the configuration lock is set.
Either the components (the Sun
StorEdge T3+ array, the switch, or the
virtualization engine) are down
(cannot be pinged) or another
SUNWsecfg command is running and
is updating the configuration (ps -ef)
If no other commands are running and
you believe the configuration lock
might be set in error, run the
removelocks command.