Sun Microsystems 3900 Series Computer Drive User Manual


 
64 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide March 2002
TABLE 6-1 lists the switch events.
TABLE 6-1 Storage Automated Diagnostic Environment Event Grid for Switches
Cat Component EventType Sev Action Description Information/Action
switch port statistics Log Yellow Y [ Info/Action ]
Change in port
statistics on switch
diag156-sw1b
(ip=192.168.0.31)
Information: The
switch has reported
a change in an error
counter. This could
indicate a failing
component in the
link.
Action:
Check the Topology
GUI for any link
errors.
Run linktest on the
link to isolate the
failing FRU.Quiesce
I/O on the link
before running
linktest.
switch chassis.fan Alarm Yellow chassis.fan.1 status
changed from OK
switch chassis.power Alarm Yellow [
Info ]
chassis.power.1 status
changed from OK
This event monitors
changes in the
status of the chassis’
power supply, as
reportedbySANbox
chassis_status.
switch chassis.temp Alarm Yellow [
Info ] chassis.temp.1
status changed from
OK
This event monitors
changes in the
status of the chassis’
temperature supply,
as reported by
SANbox
chassis_status.
switch chassis.zone Alarm Yellow [
Info ] Switch sw1a
was rezoned: [ new
zones ...]
This event reports
changes in the
zoning of a switch.