Sun Microsystems 3900 Series Computer Drive User Manual


 
26 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide March 2002
An error in the A1/B1 FC link can also cause a device to enter the “unusable” state
in cfgadm. In this case, the output for luxadm -e port will show that a device that
was “connected” changed to an “unconnected” state.
CODE EXAMPLE 3-2 cfgadm -al Display
FRU Tests Available for A1/B1 FC Link Segment
HBA—qlctest(1M)
Available only if the Storage Automated Diagnostic Environment is installed
on a data host
Causes HBA to go “offline” and “online” during tests
Switch switchtest(1M)
Can be run while the link is still cabled and online (connected to HBA)
You must specify a payload of 200 bytes or less when testing the A1/B1 FC
link, while the link is connected to the HBA (limitation in HBA ASIC).
Can be run only from the Storage Service Processor
The dev option to switchtest is in the following format:
Port:IP-Address:FCAddress
The FCAddress can be set to 0x0
...
# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 scsi-bus connected configured unknown
c0::dsk/c0t0d0 disk connected configured unknown
c0::dsk/c0t1d0 disk connected configured unknown
c1 scsi-bus connected configured unknown
c1::dsk/c1t6d0 CD-ROM connected configured unknown
c2 fc-fabric connected configured unknown
c2::210100e08b23fa25 unknown connected unconfigured unknown
c2::2b000060220041f4 disk connected configured unknown
c3 fc-fabric connected configured unknown
c3::2b000060220041f9 disk connected configured unusable
c4 fc-private connected unconfigured unknown
c5 fc connected unconfigured unknown