Tektronix TDS 700C Graphics Tablet User Manual


 
Triggering on Waveforms
TDS 500C, TDS 600B, & TDS 700C User Manual
3–107
There are two different ways to delay the acquisition of waveforms: delayed runs
after main and delayed triggerable. Only delayed triggerable uses the delayed
trigger system. Delayed runs after main looks for a main trigger, then waits a
user-defined time, and then starts acquiring. (See Figure 3–50.)
Wait User-specified
Time
Acquire
Data
Wait for
Main
Trigger
Figure 3–50: Delayed Runs After Main
Delayed triggerable looks for a main trigger and then, depending on the type of
delayed trigger selected, makes one of the three types of delayed triggerable mode
acquisitions: After Time, After Events, or After Events/Time. Study Figure 3–51 to
understand the sequence the oscilloscope goes through for each delayed mode.
Wait for
Main
Trigger
Delayed Triggerable
After Time
Wait for
Delayed
Trigger
Event
Acquire
Data
Wait the
User-specified
Number of Delayed
Trigger Events
Wait User-specified
Time
Wait
User-specified
Time
Wait the
User-specified
Number of Delayed
Trigger Events
Delayed Triggerable
After Events
Delayed Triggerable
After Events/Time
Figure 3–51: Delayed Triggerable
The oscilloscope is always acquiring samples to fill the pretrigger part of the
waveform record. When and if delay criteria are met, it takes enough posttrigger
samples to complete the delayed waveform record and then displays it. Refer to
Figure 3–52 for a more detailed look at how delayed records are placed in time
relative to the main trigger.