Texas Instruments TNETX4090 Switch User Manual


 
TNETX4090
ThunderSWITCH II
9-PORT 100-/1000-MBIT/S ETHERNET
SWITCH
SPWS044E – DECEMBER 1997 – REVISED AUGUST 1999
71
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
EEPROM interface
For further information on EEPROM interface timing, refer to the 24C02 or 24C08 serial EEPROM data sheets.
EEPROM writes (see Figure 27)
NO. MIN MAX UNIT
1 t
su(EDIO:Start)
Setup time, start condition during ECLK high 383 t
c
2 t
h(EDIO:Start)
Hold time, start condition during ECLK high 383 t
c
3 t
h(EDIO:Data)
Hold time, data after ECLK 0 t
c
4 t
su(EDIO:Data)
Setup time, data before ECLK 383 t
c
5 t
w(ECLK)
Pulse duration, ECLK low during start/stop 766 t
c
6 t
w(ECLK)
Pulse duration, ECLK high during start/stop 766 t
c
7 t
w(ECLK:Data)
Pulse duration, ECLK high during data 383 t
c
8 t
w(ECLK:Data)
Pulse duration, ECLK low during data 766 t
c
9 f
clock(ECLK)
Clock frequency, ECLK 98 kHz
EDIO (out)
7 8
421
3
5 6
ECLK
Figure 27. EEPROM Writes
EEPROM reads (see Figure 28)
NO. MIN MAX UNIT
1 t
su(EDIO)
Setup time, EDIO (in) before ECLK 10 ns
2 t
h(EDIO)
Hold time, EDIO (in) after ECLK 0 ns
ECLK
1
2
EDIO (in)
Figure 28. EEPROM Reads