5. PROGRAMMING OPERATIONS
EO1-11138
5-38
5.4 How to Access a Program Item
(1 to 99)
*
(See NOTE)
Repeat for other groups * (For sequentially programming Group Codes
(max. 99 groups) and Names, the code specification can be skipped.)
ex.) To set “BEER” for a PLU group 2
Mode Lock: SET
Enter 29, depress [X].
2 [ST] BEER [ST] [AT/TL]
Journal Print
29 [X] |PLU Group Code| [ST] Character Entries [ST] [AT/TL]
*
SET
*
02-06-1999 12:34
PROGRAMMING PLU GROUP
01 PLU GP01
02 PLU GP02
03 PLU GP03
04 PLU GP04
05 PLU GP05
06 PLU GP06
07 PLU GP07
08 PLU GP08
Please input item No.
0.00
Pg up Pg dw Enter
PLU Group Name Programming (Submode 29)
This programming is used to set each PLU group name. Grouping of each PLU should be set in the PLU
Table Programming (Submode 4).
CONDITION Any time outside a sale When you enter 29 and depress the [X] key,
the screen shown below will appear.
OPERATION Mode Lock: SET
P29
PLU GROUP
02
BEER
0050 16:52TM
NOTE: A maximum of 16 regular-sized characters may be set for each PLU Group name. One double-sized
character occupies two regular-sized characters’ space. Also see the CHARACTER ENTRIES at the
beginning of this chapter. If no name is programmed for a PLU Group, an auto-preset data is assigned
as the PLU Group Name (PLU GPxx; xx = PLU Group Code 01 to 99).