e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE June 2005 © TOSHIBA TEC
2 - 2
E110 Paper misfeeding ADU misfeeding (Paper not reaching the registra-
tion sensor): The paper which has passed through
ADU does not reach the registration sensor during
duplex printing.
Ch.5.1.2
E120 Bypass misfeeding (Paper not reaching the regis-
tration sensor): The paper fed from the bypass tray
does not reach the registration sensor.
Ch.5.1.2
E130 Upper drawer misfeeding (Paper not reaching the
upper drawer feed sensor): The paper fed from the
upper drawer does not reach the upper drawer feed
sensor.
Ch.5.1.2
E140 Lower drawer misfeeding (Paper not reaching the
lower drawer feed sensor): The paper fed from the
lower drawer does not reach the lower drawer feed
sensor.
Ch.5.1.2
E150 PFP upper drawer misfeeding (Paper not reaching
the PFP upper drawer feed sensor): The paper fed
from the PFP upper drawer does not reach the PFP
upper drawer feed sensor.
Ch.5.1.2
E160 PFP lower drawer misfeeding (Paper not reaching
the PFP lower drawer feed sensor): The paper fed
from the PFP lower drawer does not reach the PFP
lower drawer feed sensor.
Ch.5.1.2
E190 LCF misfeeding (Paper not reaching the LCF feed
sensor): The paper fed from the LCF does not
reach the LCF feed sensor.
Ch.5.1.2
E200 Paper transport jam Upper drawer transport jam (Paper not reaching the
registration sensor): The paper does not reach the
registration sensor after it has passed the upper
drawer feed sensor.
Ch.5.1.3
Error code Classification Contents Troubleshooting