e-STUDIO281c/351c/451c TROUBLESHOOTING June 2005 © TOSHIBA TEC
5 - 68
[CE00] Communication error between finisher and puncher unit
MJ-1023/1024 (When MJ-6004 is installed)
Is the problem solved by turning OFF and ON the power of the equipment?
È
YESÆ End.
NO
Is the wiring between the finisher controller PC board and punch controller PC board correct?
È
NO Æ Correct the wiring.
YES
1) Replace the finisher controller PC board.
2) Replace the punch controller PC board.