Tests and Diagnostics
TECRA A11/S11/P11/Satellite Pro S500 Series Maintenance Manual (960-784) [CONFIDENTIAL] 3-11
Step 3
The next message screen is displayed.
* Re-push (NUMLOCK) key and any other key press key to continue.
Check 1: According to a message, the [NumLock] key of a ten key is pressed and then the
any other key is pressed.
Check 2 Lighting of NumLock LED of a ten key is checked. It progresses to Step 7 after this
test routine.
When the above test cannot be performed, since KB type is Un match, the Any key is pressed
and it progresses to Step 6.
Step 4
In the case of a ten-key-less keyboard, the [O] key is pressed, and then it presses the [Enter]
key.
The next message screen is displayed.
* KB type is Without 10 key...Push (Fn+f10)(K)
Check 1: Lighting of Arrow LED of F10 key lower part is checked.
Check 2: According to a message, [Fn] + [F10] Key is pushed and then the [k] key is pressed.
Step 5
The next message screen is displayed.
* Re-push (Fn +f10) key and any other key press any key to continue...
Check 1: According to a message, [Fn]+[F10] Key is pushed and then the any other key is
pressed.
Check 2: Putting out lights of Arrow LED of F10 key lower part is checked.
It progresses to Step 7 after this test routine.
When the above test cannot be performed, since KB type is Un match, the Any key is pressed
and it progresses to Step 6.