Toshiba P11 Personal Computer User Manual


 
Tests and Diagnostics
TECRA A11/S11/P11/Satellite Pro S500 Series Maintenance Manual (960-784) [CONFIDENTIAL] 3-175
6) Boot Media
If the system is booted from the CD when both the CD and the USB memory that contain
WinPE T&D are connected to the PC, T&D in the USB memory starts up.
Also, when a bootable CD is not inserted in the CD drive when the system is booted from the
USB memory, the ODD test fails with an error because the ODD test file is only contained in
this CD. However, this error should be solved by inserting the bootable CD.
7) Timer Test
If the Timer test and other test are executed simultaneously (Multitasking), the error time
displayed in the test log is not displayed correctly.
8) CD Boot
After Winpe is selected on the Multiboot selection screen when the system is booted from the
CD, the”Press any Key to boot from CD or DVD…” message is displayed but only the
[ENTER] key is valid.
3.37.3 Notices and Restrictions (Freedos)
1) USB Boot
If you boot the system
from the USB memory, the FDD test cannot be executed. Use CD
Boot.
2) FDD Test
If the USB FDD drive or the floppy disk on the disk drive is removed during an FDD test, a
time-out error occurs and then the program hangs up. Do not remove the FDD drive or the
floppy disk during the FDD test.