Toshiba TMP92CM22FG Computer Hardware User Manual


 
TMP92CM22
2007-02-16
92CM22-224
4.5 Serial Channel Timing (I/O interface mode)
Note: Symbol “X” in the following table means the period of clock “f
SYS
”, it’s same period of the system clock
“f
SYS
” for CPU core. The period of f
SYS
depends on the clock gear setting or changing high-speed
oscillator/low-speed oscillator and so on.
(1) SCLK input mode
Variable
f
SYS
=
20 MHz
(fc = 40 MHz)
f
SYS
=
125 kHz
(fc = 4 MHz)
Parameter Symbol
Min Max Min Max Min Max
Unit
SCLK period
t
SCY
16X 0.8 128 μs
Output data SCLK rising/falling* t
OSS
t
SCY
/2 4X 110 90 31890 ns
SCLK
rising/falling
*
Output data hold t
OHS
t
SCY
/2 + 2X + 0 500 80000 ns
SCLK
rising/falling
*
Input data hold t
HSR
3X + 10 160 24010 ns
SCLK
rising/falling
Valid data input t
SRD
t
SCY
0 800 128000 ns
Valid data input SCLK rising/falling t
RDS
0 0 0 ns
*) SCLK rinsing/falling edge: The rising edge is used in SCLK rising mode.
The falling edge is used in SCLK falling mode.
Note: Value of f
SYS
= 20 MHz, 125 kHz is value if t
SCY
= 16X.
(2) SCLK output mode
Variable
f
SYS
=
20 MHz
(fc = 40 MHz)
f
SYS
=
125 kHz
(fc = 4 MHz)
Parameter Symbol
Min Max Min Max Min Max
Unit
SCLK period t
SCY
16X 8192X 0.8 409.6 128 65536 μs
Output data SCLK rising/falling* t
OSS
t
SCY
/2 40 360 3960 ns
SCLK
rising/falling
*
Output data hold t
OHS
t
SCY
/2 40 360 3960 ns
SCLK
rising/falling
*
Input data hold t
HSR
0 0 0 ns
SCLK
rising/falling
Valid data input t
SRD
t
SCY
1X
180
409.4 65528 ns
Valid data input SCLK rising/falling t
RDS
1X + 180 230 8180 ns