Toshiba Z300 Server User Manual


 
External Unit Setup
Installing SCSI device
130
(2) SCSI connector ( )
Used to connect the System Unit.
See “How to connect peripheral devices” on page 26.
Installing SCSI device
The installation of a SCSI device requires special knowledge or
technology. If you have no experience in installing a SCSI device
or require assistance, consult your authorized MAGNIA service
provider.
Terminator
The SCSI bus is terminated at the SCSI controller and dedicated
External Device Bay Unit Z1. Set the terminator of the installed
SCSI device to disabled.
SCSI ID
The SCSI ID of the SCSI device to be installed is set so that it does
not overlap with the SCSI ID of other devices installed.
The SCSI ID of the previously installed device is “5”.
When installing the second External Device Bay Unit Z1, change
the SCSI ID in the procedure below.
Changing the SCSI ID
To change the SCSI ID follow the procedure described below,
while referring to “Before starting operation” on page 48:
1 If the server is running, shut it down and turn off the power.
NOTE: Installing the SCSI device while the power is on may
damage the server and SCSI device.
2 Disconnect the AC power cable.