96
Searching and Storing
1-5 sec The scanner waits the set amount of
time after the transmission ends before
resuming.
Note: The default setting is 2 sec.
• Set Attenuator This setting controls the
attenuator for search operation. Select your
setting, then press the scroll control.
Off The attenuator is off.
On Reception is attenuated by about 18 dB.
Note: Turn on this setting if you are near other
strong signal sources. Attenuation sometimes helps
to reduce interference and desensitization that
strong signals create.
• Search with Scan This setting controls how
search with scan works.
• Set Lockout This setting controls whether
the system is scanned when its quick key is
enabled. Rotate the scroll control to select your
setting, then press the scroll control.
Locked - the system is not scanned
Unlocked - the system is scanned
Note: You can also lock or unlock a system by
pressing , selecting the system, then
pressing + L/O.
• Set Hold Time This setting controls how
many seconds the scanner scans a system
before moving to the next unlocked system.
Enter a value from 0-255, then press the scroll
control to save the setting.
Notes:
• If you select 0, the scanner stays on the
system for a minimal time (only long enough
to check current system activity).
• The default setting is 2 seconds for each
system.
Func
Func
BCD396T Paper OM.fm Page 96 Wednesday, March 30, 2005 8:36 PM