Unisys EFP9800 Printer User Manual


 
Diagnostics and Print Tests
3255 4073002 321
Exit Data Scope Mode
1. Turn the printer off.
2. Turn the printer to the back to access the DIP switches and write down the
current switch settings.
3. Set the DIP switches to the following settings:
Switch
1
Switch
2
Switch
3
Switch
4
Switch
5
Switch
6
Switch
7
Switch
8
ON OFF OFF OFF OFF ON OFF OFF
4. Turn the printer back on to take the printer out of Data Scope mode.
The red Paper Status LED blinks once to indicate that the printer is out of
Data Scope mode.
5. Turn the printer off and reset the DIP switches to what they were when you
started.
6. For normal operation settings, see Switch Settings in section 5.
7. Turn the printer back on.
Enabling or Disabling the Cover Open Switch
Use this procedure to enable or disable the cover open switch. The cover open
switch is optional, and may not be available on all printers.
Note: The EFP9800 FLASHADMIN software utility can also be used for
enabling or disabling the cover open switch. This utility is included
in the EFP9800-SW1 style package.
Caution
The DIP switches are set at the factory to predetermined settings. Change the
settings carefully to avoid changing other functions.
Note: Secure the roller assembly in a closed position to eliminate the
nuisance noise form occurring when the receipt assembly is not
being used.