43 VIDEO STANDARD SELECT
Function
The external control equipment sets the VIDEO STANDARD of the plasma monitor.
Transmission Data
DFH 80H 60H 5CH 01H DATA00 CKS
DATA00: 01H: 3.58NTSC
02H: 4.43NTSC
03H: PAL
04H: SECAM
05H: AUTO1
0BH: PAL60
0CH: AUTO2
0DH: PAL-M
0EH: PAL-N
ACK
7FH 60H 80H 5CH 01H DATA00 CKS
DATA00: 01H: 3.58NTSC
02H: 4.43NTSC
03H: PAL
04H: SECAM
05H: AUTO1
0BH: PAL60
0CH: AUTO2
0DH: PAL-M
0EH: PAL-N
44 FREQUENCY REQUEST
Function
The external control equipment inquires the Horizontal frequency, Vertical frequency,
Horizontal sync polarity, Vertical sync polarity, Mode, and Resolution of the plasma
monitor.
Transmission Data
1FH 80H 60H 26H 00H CKS
ACK
7FH 60H 80H 26H 0BH DATA00 to DATA10 CKS
Horizontal frequency
DATA00: Integer part 00H: 0 (No signal: 00H)
|
FFH: 256
DATA01: One decimal place 00H: 0 (No signal: 00H)
|
09H: 9
Vertical frequency
DATA02: Integer part 00H: 0 (No signal: 00H)
|
FFH: 256
DATA03: One decimal place 00H: 0 (No signal: 00H)
|
09H: 9
Horizontal sync polarity
DATA04: 00H: -
01H: Positive
02H: Negative