Vidikron VP-42 Computer Monitor User Manual


 
86
12 IMAGE MEM. SELECT
Function
The external control equipment sets the picture mode of the plasma monitor.
Transmission Data
DFH 80H 60H 0AH 01H DATA00 CKS
DATA00: 01H: MEMORY
02H: LW BLK1
03H: CONTRAST
04H: FACTORY
ACK
7FH 60H 80H 0AH 01H DATA00 CKS
DATA00: 01H: MEMORY
02H: LW BLK1
03H: NORMAL
04H: FACTORY
13 WHITE BAL. SELECT
Function
The external control equipment changes the WHITE BAL. of the plasma monitor.
Transmission Data
DFH 80H 60H 00H 01H DATA00 CKS
DATA00: 00H: 5400K
DATA01: 01H: 6500K
DATA02: 03H: 9300K
ACK
7FH 60H 80H 00H 01H DATA00 CKS
DATA00: 00H: 5400K
01H: 6500K
02H: 8500K
03H: 9300K
NOTE: Set so that at the selection of 5400K, 6500K, 8500K
of WHITE BAL. change of the following R/G/B GAIN data
cannot be accepted.
External Controls